MIYACHI TECHNOS CORPORATION

|Japanese
Inquiry
  • Home
  • Corp. Info
  • IR Info
  • Products
  • Support

Products

YAG Laser Welder

Allows Laser Welding of Copper, Too!

 Real-Time Power Feedback Control YAG SHG Green Pulse Laser Welder

ML-8050A
ML2650B image
  • Real-time power feedback
  • Variable mirrors
  • Waveform control
  • Power monitor
  • External communications
  • Forced air cooling
  • Dualwavelength laser system
 

SHG lasers

An SHG (second harmonic generation) laser is a green laser that uses nonlinear optic elements. It has a wavelength of 532nm, which is in the visible light range and is half that of the principle YAG laser's wavelength (1,064nm).


Spectrum

Why this is suited to copper welding

A YAG SHG laser's wavelength has a good absorbency ratio for copper and gold, about 4.5 to 20times better that of the normal YAG laser.


Laser wavelength and absorbency ratio

 

ML-8050A welding sample

Dephosphorized copper butt welding Thickness of the plates

0.08 mm

Dephosphorized copper butt welding Thickness of the plates
 

Welding conditions: 0.35 kW peak, pulse width 2.0 ms, 2 pps, 0.66 J, feed speed 0.2 mm/s

 

2-wavelength welding system

By combining a SHG YAG laser and normal YAG laser at a focus head as shown in the right picture, the welding depth and melting spot diameter on copper work-piece are greatly improved comparing to a single wave length welding.
2-wavelength welding system
 

Results of different wavelength lasers applied on copper plates

Results of different wavelength laser applied on copper plates
 

Specification

Model ML-8050A
Oscillation wavelength 532nm(YAG-SHG)
Laser output Maximum rated output 2W
Maximum rated output 2J/P
Maximum rated output 1.5kW(pulse width 1ms maximum)
Output control Pulse width 0.20 - 3ms(0.02ms steps)
Pulse repetition rate 1 - 12pps
Pulse repetition rate 32 schedules
Counter Total Counter 9 digits
Good Counter 9 digits
Available optical fiber Ø0.3-0.6mm SI type optical fiber(Ø0.3mm SI type optical system is recommended)
Branch optical system Single branch only
External communication function RS-485
Required power supply Single-phase 200/220/240VAC +10% -15% 50/60Hz
Cooling system Forced air cooling
Dimensions 310(W) X 802(D) X 700(H)mm
Mass 84kg

The specification and external design are subject to change without notice.

TOP OF PAGE