Laser Weld Checker
 

The MML-100A, Laser Weld checker measures the output power and monitors it to ensure the output to be in the preset range.

It monitors the laser output at the output end of optical fiber

MML-100A can emit an alarm signal when the actual output power would be above/below the pre-set upper/lower limit.

Detecting variance in the laser output at the optical fiber

Laser output fluctuation and optical fiber's abnormality can be detected.

 

Detecting change in the light reflected from processing points

Work distance errors, changes in the workpiece, uncleanness and damage of the protect glass, and laser output fluctuation can be detected.

Measurement data can be stored in both the internal memory chip and CF cards.

It is convenient when you wish to analyze the measured data.

 

Display (during operation)

Display (during operation)
 

You can confirm the waveform during the operation.

You can confirm in real-time the waveform during the operation.
 

Standard system configuration

Standard system configuration
 

Supports for Miyachi YAG laser welders

Model MML-100A
Sensor Detection method Optical sensor (laser output power monitor, reflected beam)
Detection wavelength 1,064nm
Main unit Input power supply voltage Single-phase 100-240 VAC ±10% 50/60 Hz
Current consumption 2 A max.
Mass ca 10 kg
Input channels Up to 4 channels
Sampling frequency 20 kHz max.
Measuring range Laser output time: 0.3 ms - 100.0 ms
Peak value: 0.3 kW - 15.0 kW
Measuring accuracy Laser output monitor: ±3% max. or ±0.3 J or less
Reflected beam monitor: ±10% max. or ±0.3 J or less
Number schedule settings Up to 32 schedules
Data saving Internal memory and CF card
Referencing rate 500 pps max.
Output unit Lens diameter Ø30mm Ø50mm
Mass ca 1.8 kg ca 3.7 kg
Environmental
condition
Ambient temperature 5-40°C (no condensation allowed)
Ambient humidity 85% RH max. (no condensation allowed)
Vibration during use Less than 2 Hz: 0.5 G max.
(intermittent vibration)/10-60 Hz 0.1 G max.
Oil mist 0.1 mg/m3max.

The specification and external design are subject to change without notice.

External Dimension (mm)

External Dimension (mm)
 